BLOG
2026/07/31Clicks:6
The rapid development of artificial intelligence (AI), high-performance computing (HPC), and cloud infrastructure is driving higher power density in modern data centers. As traditional air cooling systems approach their limits, liquid cooling has become an increasingly important solution for efficient thermal management.
A reliable liquid cooling system requires more than efficient heat transfer. Every component in the cooling loop, including hoses, must provide long-term stability, chemical compatibility, low permeability, and safe operation.
The LCH-SD fire resistant rubber hose is specifically developed for data center liquid cooling and semiconductor cooling applications, offering excellent flexibility, high-purity EPDM performance, fire resistance, and reliable coolant transportation.
Liquid cooling systems operate continuously under demanding conditions, where coolant purity, pressure stability, and material compatibility are critical.
Conventional rubber hoses may experience issues such as coolant permeation, material aging, contamination, or reduced performance after long-term operation.
For modern liquid cooling infrastructure, engineers typically require hoses with:
LCH-SD is designed to meet these requirements by combining peroxide-cured EPDM rubber technology with reinforced construction for demanding cooling environments.
The inner layer of LCH-SD is manufactured from black smooth anti-static peroxide-cured high-purity EPDM synthetic rubber.
EPDM is widely recognized for its excellent resistance to water-based cooling fluids and environmental aging.
The high-purity inner tube helps reduce:
The smooth inner surface also supports stable coolant flow and improves system cleanliness.
Fire safety is a key consideration in modern data centers and semiconductor facilities.
LCH-SD features a high-purity fire-resistant peroxide-cured EPDM outer cover with UL94-V0 flame resistance performance.
This fire-resistant structure helps improve safety in critical applications such as:
Coolant leakage and permeation can increase maintenance requirements and operating costs in liquid cooling systems.
LCH-SD provides improved gas tightness compared with standard rubber hoses, helping reduce coolant loss during long-term operation.
Benefits include:
Modern data centers often require complex hose routing inside limited spaces.
LCH-SD uses an embedded spiral steel wire reinforcement structure combined with polyester fiber or customized aramid reinforcement.
This construction provides:
The hose can be easily routed around server racks, cooling modules, and equipment connections.
The LCH-SD hose adopts a multi-layer reinforced structure designed for reliable liquid cooling applications.
Material:
Black smooth anti-static peroxide-cured high-purity EPDM synthetic rubber.
Functions:
Structure:
Polyester fiber or customized aramid yarn reinforcement with embedded spiral steel wire.
Functions:
Material:
High-purity fire-resistant peroxide-cured EPDM synthetic rubber.
Features:
| Item | Specification |
|---|---|
| Product Name | Data Center Liquid Cooling Fire Resistant Rubber Hose |
| Model | LCH-SD |
| Inner Tube Material | High Purity EPDM |
| Reinforcement | Polyester Fiber / Aramid Yarn + Spiral Steel Wire |
| Working Pressure | 10-16 Bar |
| Safety Factor | 4:1 |
| Continuous Working Temperature | -40°C to +125°C |
| Short-Term Peak Temperature | +135°C |
| Fire Rating | UL94-V0 |
| Surface | Fabric Impression |
| Available Colors | Black / Red / Blue |
| Environmental Compliance | RoHS, REACH |
| Model | ID | OD | Minimum Bend Radius | Working Pressure | Burst Pressure | Coil Length |
|---|---|---|---|---|---|---|
| LCH032-SD | 32 mm | 44 mm | 160 mm | 1.6 MPa | 6.4 MPa | 40 m |
| LCH038-SD | 38 mm | 51 mm | 190 mm | 1.0 MPa | 4.0 MPa | 40 m |
| LCH051-SD | 51 mm | 64 mm | 250 mm | 1.0 MPa | 4.0 MPa | 40 m |
| LCH064-SD | 64 mm | 78 mm | 315 mm | 1.0 MPa | 4.0 MPa | 40 m |
| LCH076-SD | 76 mm | 90 mm | 350 mm | 1.0 MPa | 4.0 MPa | 40 m |
LCH-SD is suitable for commonly used liquid cooling media, including:
Material compatibility should always be evaluated according to the specific coolant formulation and operating conditions.
LCH-SD is designed for coolant circulation systems used in:
Semiconductor manufacturing equipment requires stable temperature control and clean fluid handling.
LCH-SD provides reliable coolant transfer for precision equipment cooling applications where chemical compatibility and cleanliness are important.
The hose can also be applied in:
Choosing the correct hose is essential for maintaining long-term cooling system reliability.
Different cooling fluids require different hose materials. The hose material must maintain stable performance without affecting coolant quality.
Data centers are mission-critical facilities. Fire-resistant materials help improve overall system safety.
Server racks and cooling equipment often have limited installation space. A hose with good flexibility and a suitable bend radius simplifies system installation.
Liquid cooling systems operate continuously. Hose durability, permeability, and pressure resistance directly affect maintenance requirements and operating costs.
LCH-SD is designed for data center liquid cooling systems, semiconductor equipment cooling, AI server cooling, and other high-reliability thermal management applications.
LCH-SD is suitable for purified water, DI water, glycol-based coolants, and fluorinated cooling fluids commonly used in liquid cooling systems.
Yes. The outer cover uses fire-resistant peroxide-cured EPDM rubber with UL94-V0 flame resistance performance.
EPDM provides excellent resistance to water-based coolants, good temperature stability, and long-term durability, making it suitable for many liquid cooling applications.
As AI computing, cloud services, and high-performance servers continue to grow, liquid cooling infrastructure is becoming a key technology for next-generation data centers.
CJan Fluid Technology Co., Ltd. developed the LCH-SD fire resistant EPDM hose to provide a reliable coolant transfer solution for modern liquid cooling systems. With high-purity EPDM materials, UL94-V0 fire resistance, excellent gas tightness, and reinforced flexible construction, LCH-SD helps engineers build safer and more reliable cooling systems.