CJan Fluid Technology Co., Ltd.

BLOG

Platinum-Cured Silicone Steel Wire Hose for Pharmaceutical Cleanroom Applications

2026/08/20Clicks:7

Platinum-Cured Silicone Steel Wire Hose for Pharmaceutical Cleanroom Applications

For pharmaceutical cleanroom applications, hose selection should be based on the actual fluid, pressure, temperature, cleanliness requirements, and installation conditions—not simply on chemical resistance.

For one pharmaceutical filtration system project, the end user required a hose for pharmaceutical cleaning water and Water for Injection (WFI). The fluid was mainly neutral, with relatively low acid and alkali concentrations. A chemical hose was not suitable for the application.

After reviewing the operating conditions, CJan Fluid Technology Co., Ltd. recommended the SQ Platinum-Cured Silicone Steel Wire Reinforced Hose.

The selected 1.5-inch SQ hose can meet the project's requirements for pressure, temperature, flexibility, and clean fluid transfer.


1. Project Background

The customer specializes in the R&D, manufacturing, system integration, and on-site installation of filtration systems.

For this project, the equipment was installed in a pharmaceutical plant cleanroom. The hose is used mainly for transferring:

  • Pharmaceutical cleaning water
  • Water for Injection (WFI)
  • Neutral process water
  • Low-concentration acid or alkaline solutions

The customer specifically required a hose suitable for this type of clean application rather than a conventional chemical transfer hose.

The main operating conditions were:

Item Requirement
Industry Pharmaceutical
Application Area Pharmaceutical Cleanroom
Medium Cleaning Water / WFI
Medium Characteristics Mainly Neutral
Acid/Alkali Concentration Low
Working Pressure 1 MPa
Ambient Temperature -10°C
Hose Size 1.5 inch
Vacuum Resistance Not Required
Recommended Product SQ Platinum-Cured Silicone Hose

2. Why Was a Silicone Hose Selected Instead of a Chemical Hose?

The key point in this project was the actual process medium.

Although the application occasionally involves low-concentration acidic or alkaline solutions, the main media are pharmaceutical cleaning water and WFI. The operating conditions do not represent a typical high-corrosion chemical transfer application.

Therefore, choosing a chemical hose simply because the application involves some acid or alkali would not necessarily be the best solution.

For this project, the focus was placed on:

  • Clean fluid transfer
  • Material suitability
  • Hose cleanliness
  • Flexibility
  • Working pressure
  • Low-temperature installation
  • Equipment connection
  • Ease of handling

Based on these requirements, a platinum-cured silicone hose was considered more appropriate than a conventional chemical hose.


3. Recommended Solution: SQ Platinum-Cured Silicone Hose

The recommended product is:

SQ Platinum-Cured Silicone Steel Wire Reinforced Hose

The SQ series combines a platinum-cured silicone inner layer with a reinforced structure to provide a balance of flexibility and mechanical strength.

For this project, the selected 1.5-inch SQ hose was evaluated against the customer's 1 MPa working pressure and cleanroom application requirements.


4. Why Platinum-Cured Silicone?

Platinum-cured silicone is widely used in applications where cleanliness and material stability are important.

Compared with ordinary industrial rubber hoses, platinum-cured silicone provides several advantages for pharmaceutical and hygienic applications.

1. Suitable for Clean Fluid Applications

The silicone material is suitable for a range of clean fluid transfer applications in pharmaceutical, biotechnology, food, and related industries.

For pharmaceutical equipment, the material itself is an important part of the overall fluid path.


2. Good Flexibility

One of the practical advantages of silicone hose is its flexibility.

In pharmaceutical filtration systems, equipment layouts can vary considerably from one installation to another. Flexible hose can make it easier to connect:

  • Filtration equipment
  • Process skids
  • Cleaning systems
  • Pumps
  • Tanks
  • Other process equipment

This can also simplify installation and maintenance.


3. Steel Wire Reinforcement

The SQ hose uses a reinforced construction to improve its pressure resistance and dimensional stability.

The project requires a working pressure of:

1 MPa

Therefore, a reinforced silicone hose is more suitable than an unreinforced silicone tube for this application.

The final hose specification should always be confirmed according to the selected diameter, temperature, connection method, and actual operating pressure.


4. Suitable for Low-Temperature Installation Conditions

The project has an ambient temperature of:

-10°C

Temperature is an important consideration when selecting a silicone hose because the surrounding environment can affect hose flexibility and mechanical performance.

The SQ hose was evaluated according to the customer's actual temperature requirements.


5. Why Is Flexibility Important in Pharmaceutical Filtration Systems?

Filtration systems are often assembled from multiple pieces of equipment.

The actual installation may involve:

  • Limited space
  • Different equipment connection heights
  • Short-distance pipe routing
  • Frequent equipment maintenance
  • Temporary equipment connections
  • Cleaning and replacement operations

A flexible hose can make these connections easier to install compared with rigid piping.

For this reason, hose selection should consider not only pressure and temperature, but also the actual installation environment.


6. Project Selection Process

For this application, the selection process focused on the following factors:

Step 1 — Confirm the Medium

The main media are pharmaceutical cleaning water and WFI, with relatively low concentrations of acid and alkali.

Step 2 — Confirm the Pressure

The required working pressure is:

1 MPa

This makes a reinforced hose construction necessary.

Step 3 — Confirm Temperature

The ambient temperature is:

-10°C

The hose needs to maintain suitable flexibility and performance under the specified conditions.

Step 4 — Confirm Vacuum Requirements

The customer does not require vacuum resistance.

Therefore, there is no need to select a hose specifically designed for vacuum service.

Step 5 — Confirm Size

The required hose size is:

1.5 inch

Step 6 — Match the Material

Since the application is primarily clean water and pharmaceutical fluid transfer rather than high-concentration chemical transfer, the SQ platinum-cured silicone hose was recommended.


7. SQ Hose for Pharmaceutical Applications

The SQ series can be considered for various clean fluid applications, depending on the actual operating conditions.

Typical applications include:

  • Pharmaceutical equipment
  • Filtration systems
  • Biopharmaceutical processing
  • Clean water transfer
  • WFI-related equipment
  • Cleaning systems
  • Process skids
  • Food and beverage equipment
  • Hygienic fluid transfer

The actual hose specification should always be confirmed based on the medium, concentration, temperature, pressure, connection, and applicable regulatory requirements.


8. What Should You Consider When Choosing a Pharmaceutical Hose?

Choosing a pharmaceutical hose should start with the actual process conditions.

Fluid

Is the medium WFI, purified water, cleaning solution, buffer, chemical solution, or another process fluid?

Pressure

What is the normal working pressure and maximum pressure?

Temperature

Consider both the fluid temperature and the ambient temperature.

Cleanliness

Determine whether the application requires a hygienic or high-purity hose.

Flexibility

Consider the minimum bend radius and the available installation space.

Vacuum

Confirm whether the system will experience suction or negative pressure.

Connection

The hose should also be matched with the required sanitary fitting, clamp, barb, or other connection method.


9. Project Summary

This project was for a pharmaceutical plant cleanroom, where the customer needed a hose for pharmaceutical cleaning water and WFI transfer.

The main conditions were:

1.5-inch size + 1 MPa working pressure + -10°C ambient temperature + no vacuum requirement

The media were mainly neutral, with low concentrations of acid and alkaline solutions.

After reviewing the application, CJan Fluid Technology recommended:

SQ Platinum-Cured Silicone Steel Wire Reinforced Hose

The SQ hose provides a combination of platinum-cured silicone material, reinforcement, flexibility, and pressure capability, making it a suitable option for this type of pharmaceutical clean fluid application.

The key to the selection was not simply choosing the hose with the highest chemical resistance. Instead, the hose was matched to the actual medium and operating environment.


About CJan Fluid Technology Co., Ltd.

CJan Fluid Technology Co., Ltd. provides hose and fluid connection solutions for pharmaceutical, biopharmaceutical, semiconductor, food, chemical, and new energy applications.

Our product range includes:

  • Platinum-cured silicone hoses
  • Pharmaceutical silicone hoses
  • PFA tubing and hoses
  • PTFE hoses
  • Food-grade hoses
  • Chemical transfer hoses
  • High-purity fluid tubing
  • Hose assemblies and fluid connection components

CJan works with customers to select suitable products based on the actual medium, pressure, temperature, size, cleanliness requirements, flexibility, and installation conditions.

Related Articles
back to the top